A validation study of intraoperative performance metrics for training novice cardiac resynchronization therapy implanters.

A validation study of intraoperative performance metrics for training novice cardiac resynchronization therapy implanters.

Mascheroni, Jorio;Mont, Lluís;Stockburger, Martin;Patwala, Ashish;Retzlaff, Hartwig;Gallagher, Anthony G;
International journal of cardiology 2020
293
mascheroni2020ainternational

Abstract

Pacing/cardiac resynchronization therapy (CRT) implant training currently lacks a common system to objectively assess trainee ability to perform required tasks at predetermined performance levels. The purpose of this study was to primarily examine construct validity and reliability, secondarily discriminative validity of novel intraoperative performance metrics, developed for a reference approach to training novice CRT implanters.Fifteen novice and eleven experienced CRT implanters performed a 3-lead implant procedure on a virtual reality simulator. Performances were video-recorded, then independently scored using predefined metrics endorsed by an international panel of experts. First, Novice and Experienced group scores were compared for steps completed and errors made. Secondly, each group was split in two around the median score of the group and subgroup scores were compared.The mean number of scored metrics per performance was 108 and the inter-rater reliability for scoring was 0.947. Compared with novices, experienced implanters completed more procedural Steps correctly (mean 87% vs. 73%, p = 0.001), made fewer procedural Errors (6.3 vs. 11.2, p = 0.005), Critical Errors (1.8 vs. 4.4, p = 0.004), and total errors (8.1 vs. 15.6, p = 0.002). Furthermore, the differences between the two Novice subgroups were 25% for steps completed correctly and 94% for total errors made (p < 0.001); the differences between the two Experienced subgroups were respectively 16% and 191% (p < 0.001).The procedure metrics used in this study reliably distinguish novice and experienced CRT implanters' performances. The metrics further differentiated performance levels within a group with similar experience. These performance metrics will underpin quality-assured novice implanter training.

Citation

ID: 97793
Ref Key: mascheroni2020ainternational
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
97793
Unique Identifier:
S0167-5273(20)30135-2
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet