vitrectomía pars plana y reimplante de lente intraocular en surco pars plana vitrectomy and intraocular lens repositioning in the sulcus

vitrectomía pars plana y reimplante de lente intraocular en surco pars plana vitrectomy and intraocular lens repositioning in the sulcus

;Alejandro Guerra García;Luis Curbelo Cunill;Frank Eguía Martínez;María del Carmen Rivas Canino
journal of the chinese chemical society 2010 Vol. 23 pp. 836-846
192
garca2010revistavitrectoma

Abstract

Se presentó un caso de lente intraocular luxado a vítreo en paciente con conteo bajo de células endoteliales e intolerancia a lentes de contacto. Se practicó vitrectomía pars plana con reimplante de lente en surco ciliar con el objetivo de demostrar la fiabilidad de la técnica para casos que presenten condiciones adecuadas y situaciones especiales. Se revisó la bibliografía para conocer las tendencias actuales con respecto al manejo de esta patología. El paciente alcanzó una agudeza visual de 20/30. El lente permaneció estable en el surco 3 meses después de practicada la vitrectomía. El manejo de esta entidad debe ser personalizado. La técnica utilizada debe ser siempre la primera opción de tratamiento y parece ser segura en casos cuidadosamente escogidos.
A case of dislocated intraocular lens moved to the vitreous cavity in a patient with low endothelial cell count and contact lens intolerance was reported. A pars plana vitrectomy with lens repositioning was performed to demonstrate the safety of this technique for some special cases under adequate conditions. The literature was reviewed to learn about the current management of this pathology. Finally, patient's best visual acuity was 20/30. The stability of the lens was confirmed three month l after the vitrectomy. Management of this disorder should be customized. This technique should be considered as the first option of treatment and seems to be safe in selected cases.

Citation

ID: 130698
Ref Key: garca2010revistavitrectoma
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
130698
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet